Original factory data must be loaded in from the tape. However, there is a memory clearing function that may stop any unusual problems occurring in the unit. All of the sounds will be erased.

1. Power off, then make the following settings:

OCTAVE TRANSPOSE: NORM
LFO TRIG MODE: MAN
DCO PWM MODE SWITCH: ENV
HPF CUTOFF FREQ slider: All the way up
VCF ENV Polarity switch: Down position
VCA Control Signal Selector switch: GATE

2. Power on while holding down the CHORUS OFF and II buttons.

When you need help, Sweetwater has the answers!

Our knowledge base contains over 28,000 expertly written tech articles that will give you answers and help you get the most out of your gear. Our pro musicians and gear experts update content daily to keep you informed and on your way. Best of all, it’s totally FREE, and it’s just another reason that you get more at Sweetwater.com.