How do I initalize my DM24?
1. With the power OFF hold down the 2nd F button (far left of the board), the HIGH button (just above in the EQ section) and the ” – ” button (just to the right in the LIBRARY section) while you turn the power ON.
2. The DM-24 will boot to DIAGNOSTIC MODE. As soon as you see DIAGNOSTIC MODE on the display you may release the 2nd F, HIGH and ” – ” buttons.
3. Use the “Down cursor key” to move the indicator to SRAM INIT (NOT SRAM INIT for factory TEST) and press ENTER.
4. Press ENTER again to confirm when prompted. A check mark will appear in the box next to SRAM INIT on the display.
5. Use the “Down cursor key” to move the indicator to FLASH INFORMATION CLEAR and press ENTER.
6. Press ENTER again to confirm when prompted. A check mark will appear in the box next to FLASH INFORMATION CLEAR on the display.
7. Use the “Down cursor key” to move the indicator to EXIT and press ENTER. This will reset the DM-24 back to the original factory settings and the DM-24 will reboot.
When you need help, Sweetwater has the answers!
Our knowledge base contains over 28,000 expertly written tech articles that will give you answers and help you get the most out of your gear. Our pro musicians and gear experts update content daily to keep you informed and on your way. Best of all, it’s totally FREE, and it’s just another reason that you get more at Sweetwater.com.