How can I use SMUX for 96K audio between my Rosetta800 and my M-Audio Firewire 1814

The routing has to be:

BNC Wordclock cable OUT of the Rosetta 800
to the Wordclock INPUT on the Firewire1814

Optical cable plugged into the Apogee Rosetta800 SMUX out
to the Firewire1814 Adat IN
Also Optical cable from the 1814 Adat out to the Apogee
Rosetta SMUX Input

Settings on the front panel of the Apogee need to be:
Sample Rate to 96Khz
Source to Digital Outs: Analog
Source to Analog Out: ADAT and SMUX

In the Firewire1814 Control Panel, Hardware Tab under
Digital Port Selection, choose ADAT and make sure to
click on the adat(S/MUX) button.
Sync source needs to be set to WORD CLOCK

When you need help, Sweetwater has the answers!

Our knowledge base contains over 28,000 expertly written tech articles that will give you answers and help you get the most out of your gear. Our pro musicians and gear experts update content daily to keep you informed and on your way. Best of all, it’s totally FREE, and it’s just another reason that you get more at Sweetwater.com.