Distortion or noise when transferring via TDIF from Pro Tools 5.3 to Tascam DA-88

Performing a TDIF transfer from the 192 I/O to a DA-88 with Pro Tools 5.3 will result in full code displayed across all 8 channels on the DA-88 and distorted signal. It is possible to transfer via TDIF from the DA-88 into the 192 I/O. This problem does NOT exist with DA-98R transfers (even with the DA-98 set to emulate a DA-88).
Updating to Pro Tools 5.3r4 and higher resolves this problem. Pro Tools 5.3r4 also requires that the following software be updated to version 5.3r4: DHS.shlb, DSI.shlb, Digidesign Direct I/O, and DAE

IMPORTANT: It is also required that a 75-ohm shunt terminator be placed on the Word Sync Input of the DA-88. (The DA-88 will not lock to the Word Clock output of the 192 Digital I/O or 192 I/O without a terminator in place.) Terminating the Word Sync Input of the DA-88 can be accomplished by using a T-connector (one of the “t’s” has the terminator on it, the other the Word Clock cable from the 192/192 Digital I/O) or by using an in-line terminator.

When you need help, Sweetwater has the answers!

Our knowledge base contains over 28,000 expertly written tech articles that will give you answers and help you get the most out of your gear. Our pro musicians and gear experts update content daily to keep you informed and on your way. Best of all, it’s totally FREE, and it’s just another reason that you get more at Sweetwater.com.