{"id":4987,"date":"2001-08-21T00:00:00","date_gmt":"2001-08-21T00:00:00","guid":{"rendered":"http:\/\/www.sweetwater.com\/sweetcare\/?p=4987"},"modified":"2007-04-27T00:00:00","modified_gmt":"2007-04-27T00:00:00","slug":"motu-2408-24i-1224-2496-308-load-control-panel","status":"publish","type":"articles","link":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/","title":{"rendered":"My MOTU 2408, 24i, 1224, 2496, or 308 won&#8217;t load the control panel and has a &#8216;RATS&#8217; error. What does this mean?"},"content":{"rendered":"<p>This error typically shows up during Windows bootup or loading the PCI324 console, but is possible to appear when installing the card.<\/p>\n<p>This message can mean one of 3 problems:<\/p>\n<p>1. The card is not seated properly in the PCI slot. Simply remove and reinsert, making sure all pins are contacting and even.<\/p>\n<p>2. You have a VIA Tech chipset on your motherboard (Check out the type of USB controller in your device manager &#8211; Right click on My  Computer, Properties, Device Manager, USB controllers. You&#8217;ll either have AMD, SIS, VIA, or Intel. This is typically the type of chipset on your motherboard)<\/p>\n<p>If you have a VIA Tech chipset, go to their homepage at http:\/\/www.viatech.com\/ and download their 4-in-1 drivers. These are updated Windows drivers for many of the basic operations performed on your motherboard, and can eliminate this problem.<\/p>\n<p>3. Your PCI-324 card is defective. Call Sweetwater Tech Support for service.<\/p>\n","protected":false},"featured_media":0,"template":"","categories":[],"tags":[34728,34854,34857,34858,34729],"storecat":[],"itemids":[17611,17460,17459],"manufacturers":[33566],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"description\" content=\"Check out the My MOTU 2408, 24i, 1224, 2496, or 308 won&#039;t load the control panel and has a &#039;RATS&#039; error. What does this mean? page at Sweetwater \u2014 the world&#039;s leading music technology and instrument retailer!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"My MOTU 2408, 24i, 1224, 2496, or 308 won&#039;t load the control panel and has a &#039;RATS&#039; error. What does this mean? - SweetCare\" \/>\n<meta property=\"og:description\" content=\"This error typically shows up during Windows bootup or loading the PCI324 console, but is possible to appear when installing the card. This message can mean one of 3 problems: 1. The card is not seated properly in the PCI slot. Simply remove and reinsert, making sure all pins are contacting and even. 2. You [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/\" \/>\n<meta property=\"og:site_name\" content=\"SweetCare\" \/>\n<meta property=\"article:modified_time\" content=\"2007-04-27T00:00:00+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/\",\"name\":\"SweetCare\",\"description\":\"Service and Support\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/#webpage\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/\",\"name\":\"My MOTU 2408, 24i, 1224, 2496, or 308 won't load the control panel and has a 'RATS' error. What does this mean? - SweetCare\",\"isPartOf\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\"},\"datePublished\":\"2001-08-21T00:00:00+00:00\",\"dateModified\":\"2007-04-27T00:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"My MOTU 2408, 24i, 1224, 2496, or 308 won&#8217;t load the control panel and has a &#8216;RATS&#8217; error. What does this mean?\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"description":"Check out the My MOTU 2408, 24i, 1224, 2496, or 308 won't load the control panel and has a 'RATS' error. What does this mean? page at Sweetwater \u2014 the world's leading music technology and instrument retailer!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/","og_locale":"en_US","og_type":"article","og_title":"My MOTU 2408, 24i, 1224, 2496, or 308 won't load the control panel and has a 'RATS' error. What does this mean? - SweetCare","og_description":"This error typically shows up during Windows bootup or loading the PCI324 console, but is possible to appear when installing the card. This message can mean one of 3 problems: 1. The card is not seated properly in the PCI slot. Simply remove and reinsert, making sure all pins are contacting and even. 2. You [&hellip;]","og_url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/","og_site_name":"SweetCare","article_modified_time":"2007-04-27T00:00:00+00:00","twitter_card":"summary","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website","url":"https:\/\/www.sweetwater.com\/sweetcare\/","name":"SweetCare","description":"Service and Support","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/#webpage","url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/","name":"My MOTU 2408, 24i, 1224, 2496, or 308 won't load the control panel and has a 'RATS' error. What does this mean? - SweetCare","isPartOf":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website"},"datePublished":"2001-08-21T00:00:00+00:00","dateModified":"2007-04-27T00:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/motu-2408-24i-1224-2496-308-load-control-panel\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sweetwater.com\/sweetcare\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/"},{"@type":"ListItem","position":3,"name":"My MOTU 2408, 24i, 1224, 2496, or 308 won&#8217;t load the control panel and has a &#8216;RATS&#8217; error. What does this mean?"}]}]}},"_links":{"self":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/4987"}],"collection":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/types\/articles"}],"version-history":[{"count":0,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/4987\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/media?parent=4987"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/categories?post=4987"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/tags?post=4987"},{"taxonomy":"storecat","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/storecat?post=4987"},{"taxonomy":"itemids","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/itemids?post=4987"},{"taxonomy":"manufacturers","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/manufacturers?post=4987"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}