{"id":398,"date":"1998-10-19T00:00:00","date_gmt":"1998-10-19T00:00:00","guid":{"rendered":"http:\/\/www.sweetwater.com\/sweetcare\/?p=398"},"modified":"2007-04-27T00:00:00","modified_gmt":"2007-04-27T00:00:00","slug":"adat-brc-d8b-digital-transfer-issues","status":"publish","type":"articles","link":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/","title":{"rendered":"ADAT, BRC, and D8B Digital Transfer Issues"},"content":{"rendered":"<p>Nothing like being on the bleeding edge. If you are using ADATS and a BRC with your new Mackie Digital 8&#149;Bus board with light pipe connections to and from the mixer you need to make sure you have word clock connected between the BRC and the light pipe card on the mixer. This requires a BNC cable. Further, you need to make sure terminate the word clock signal. In order to do this you will need a BNC &#8220;T&#8221; connector with a 50 ohm BNC terminator. Connect the terminator to the &#8220;T&#8221; and connect the &#8220;T&#8221; to the BRC. From there just run a BNC cable to the 8&#149;Bus. Sweetwater Sound should have these parts in stock by the time most of you read this.<\/p>\n","protected":false},"featured_media":0,"template":"","categories":[],"tags":[],"storecat":[],"itemids":[20979],"manufacturers":[33516],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"description\" content=\"Check out the ADAT, BRC, and D8B Digital Transfer Issues page at Sweetwater \u2014 the world&#039;s leading music technology and instrument retailer!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ADAT, BRC, and D8B Digital Transfer Issues - SweetCare\" \/>\n<meta property=\"og:description\" content=\"Nothing like being on the bleeding edge. If you are using ADATS and a BRC with your new Mackie Digital 8&#149;Bus board with light pipe connections to and from the mixer you need to make sure you have word clock connected between the BRC and the light pipe card on the mixer. This requires a [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/\" \/>\n<meta property=\"og:site_name\" content=\"SweetCare\" \/>\n<meta property=\"article:modified_time\" content=\"2007-04-27T00:00:00+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/\",\"name\":\"SweetCare\",\"description\":\"Service and Support\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/#webpage\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/\",\"name\":\"ADAT, BRC, and D8B Digital Transfer Issues - SweetCare\",\"isPartOf\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\"},\"datePublished\":\"1998-10-19T00:00:00+00:00\",\"dateModified\":\"2007-04-27T00:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ADAT, BRC, and D8B Digital Transfer Issues\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"description":"Check out the ADAT, BRC, and D8B Digital Transfer Issues page at Sweetwater \u2014 the world's leading music technology and instrument retailer!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/","og_locale":"en_US","og_type":"article","og_title":"ADAT, BRC, and D8B Digital Transfer Issues - SweetCare","og_description":"Nothing like being on the bleeding edge. If you are using ADATS and a BRC with your new Mackie Digital 8&#149;Bus board with light pipe connections to and from the mixer you need to make sure you have word clock connected between the BRC and the light pipe card on the mixer. This requires a [&hellip;]","og_url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/","og_site_name":"SweetCare","article_modified_time":"2007-04-27T00:00:00+00:00","twitter_card":"summary","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website","url":"https:\/\/www.sweetwater.com\/sweetcare\/","name":"SweetCare","description":"Service and Support","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/#webpage","url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/","name":"ADAT, BRC, and D8B Digital Transfer Issues - SweetCare","isPartOf":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website"},"datePublished":"1998-10-19T00:00:00+00:00","dateModified":"2007-04-27T00:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/adat-brc-d8b-digital-transfer-issues\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sweetwater.com\/sweetcare\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/"},{"@type":"ListItem","position":3,"name":"ADAT, BRC, and D8B Digital Transfer Issues"}]}]}},"_links":{"self":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/398"}],"collection":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/types\/articles"}],"version-history":[{"count":0,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/398\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/media?parent=398"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/categories?post=398"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/tags?post=398"},{"taxonomy":"storecat","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/storecat?post=398"},{"taxonomy":"itemids","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/itemids?post=398"},{"taxonomy":"manufacturers","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/manufacturers?post=398"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}