{"id":3146,"date":"1997-01-31T00:00:00","date_gmt":"1997-01-31T00:00:00","guid":{"rendered":"http:\/\/www.sweetwater.com\/sweetcare\/?p=3146"},"modified":"2012-04-17T17:57:34","modified_gmt":"2012-04-17T17:57:34","slug":"error-code-messages-da88","status":"publish","type":"articles","link":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/","title":{"rendered":"Error code messages in the DA88"},"content":{"rendered":"<p>               SERVO IC VERSION 1.00, 1.01 &#038; 1.03<br \/>S-Err 01  Mechanical problem, -tape path, guide, drum,      <br \/>                motor, etc.<br \/>S-Err 02  Irregular drum rotation speed. <br \/>S-Err 03  Combo of Errors 1 &#038; 2.<br \/>S-Err 04  Capstan motor problem.<br \/>S-Err 05  Combo of Errors 1 &#038; 4.<br \/>S-Err 06  Combo of Errors 2 &#038; 4.<br \/>S-Err 07  Combo of Errors 1,2 &#038; 4<br \/>S-Err 08  Reel (take-up or supply) problem.<br \/>S-Err 09  Combo of Errors  1 &#038; 8<br \/>S-Err OA  Combo of Errors 2 &#038; 8<br \/>S-Err 0B  Combo of Errors 1,2 &#038; 8<br \/>S-Err OC  Combo of Errors 4 &#038; 8<br \/>S-Err OD  Combo of Errors 1,4 &#038; 8<br \/>S-Err OE  Combo of Errors 2,4 &#038; 8<br \/>S-Err OF  Combo of Errors 1,2,4 &#038; 8<br \/>                SERVO IC VERSION 2.00 &#038; 2.02<br \/>S-Err 11  A mechanical mode change does not complete     <br \/>                within 5 seconds.<br \/>S-Err 21  The reels do not wind the tape when EJECT.<br \/>S-Err 31  The tape is loose<br \/>S-Err 41  During FF\/REW (100xspeed), the solenoid does<br \/>                not engage.<br \/>S-Err  02  Drum motor is driving and the drum FG is not <br \/>                 detected for more than 1.5 seconds.<br \/>S-Err 04  Capstan motor is driving and the capstan FG is <br \/>                not detected for more than 1.5 seconds<br \/>S-Err 08  Reel motor is driving and the reel is FG is not<br \/>                detected for more than 1.5 seconds<br \/>S-Err 68  In PLAY back, the reels do not start to drive <br \/>                or  do not lock for more than 1.5 seconds<br \/>S-Err 59  EJECT, the reels do not start to drive or do <br \/>                not lock for more than 1.5 seconds.<\/p>\n","protected":false},"featured_media":0,"template":"","categories":[],"tags":[33901],"storecat":[],"itemids":[],"manufacturers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"description\" content=\"Check out the  Error code messages in the DA88 page at Sweetwater \u2014 the world&#039;s leading music technology and instrument retailer!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Error code messages in the DA88 - SweetCare\" \/>\n<meta property=\"og:description\" content=\"SERVO IC VERSION 1.00, 1.01 &#038; 1.03S-Err 01 Mechanical problem, -tape path, guide, drum, motor, etc.S-Err 02 Irregular drum rotation speed. S-Err 03 Combo of Errors 1 &#038; 2.S-Err 04 Capstan motor problem.S-Err 05 Combo of Errors 1 &#038; 4.S-Err 06 Combo of Errors 2 &#038; 4.S-Err 07 Combo of Errors 1,2 &#038; 4S-Err 08 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/\" \/>\n<meta property=\"og:site_name\" content=\"SweetCare\" \/>\n<meta property=\"article:modified_time\" content=\"2012-04-17T17:57:34+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/\",\"name\":\"SweetCare\",\"description\":\"Service and Support\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/#webpage\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/\",\"name\":\"Error code messages in the DA88 - SweetCare\",\"isPartOf\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\"},\"datePublished\":\"1997-01-31T00:00:00+00:00\",\"dateModified\":\"2012-04-17T17:57:34+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Error code messages in the DA88\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"description":"Check out the  Error code messages in the DA88 page at Sweetwater \u2014 the world's leading music technology and instrument retailer!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/","og_locale":"en_US","og_type":"article","og_title":"Error code messages in the DA88 - SweetCare","og_description":"SERVO IC VERSION 1.00, 1.01 &#038; 1.03S-Err 01 Mechanical problem, -tape path, guide, drum, motor, etc.S-Err 02 Irregular drum rotation speed. S-Err 03 Combo of Errors 1 &#038; 2.S-Err 04 Capstan motor problem.S-Err 05 Combo of Errors 1 &#038; 4.S-Err 06 Combo of Errors 2 &#038; 4.S-Err 07 Combo of Errors 1,2 &#038; 4S-Err 08 [&hellip;]","og_url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/","og_site_name":"SweetCare","article_modified_time":"2012-04-17T17:57:34+00:00","twitter_card":"summary","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website","url":"https:\/\/www.sweetwater.com\/sweetcare\/","name":"SweetCare","description":"Service and Support","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/#webpage","url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/","name":"Error code messages in the DA88 - SweetCare","isPartOf":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website"},"datePublished":"1997-01-31T00:00:00+00:00","dateModified":"2012-04-17T17:57:34+00:00","breadcrumb":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/error-code-messages-da88\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sweetwater.com\/sweetcare\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/"},{"@type":"ListItem","position":3,"name":"Error code messages in the DA88"}]}]}},"_links":{"self":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/3146"}],"collection":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/types\/articles"}],"version-history":[{"count":1,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/3146\/revisions"}],"predecessor-version":[{"id":1715536,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/3146\/revisions\/1715536"}],"wp:attachment":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/media?parent=3146"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/categories?post=3146"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/tags?post=3146"},{"taxonomy":"storecat","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/storecat?post=3146"},{"taxonomy":"itemids","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/itemids?post=3146"},{"taxonomy":"manufacturers","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/manufacturers?post=3146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}