{"id":26749,"date":"2003-07-01T00:00:00","date_gmt":"2003-07-01T00:00:00","guid":{"rendered":"http:\/\/www.sweetwater.com\/sweetcare\/?p=26749"},"modified":"2007-04-27T00:00:00","modified_gmt":"2007-04-27T00:00:00","slug":"perform-self-diagnostics-kurzweil-k1000","status":"publish","type":"articles","link":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/","title":{"rendered":"How do I perform self-diagnostics on the Kurzweil K1000?"},"content":{"rendered":"<p>Warning &#8211; the RAM test will erase the K1000&#8217;s memory and will delete all of the program changes you have made, including the master parameter and control settings.<\/p>\n<p>Also &#8211; Set the volume to minimum; The sound ROM test generates full-volume waveforms which can damage your audio system.<\/p>\n<p>To enter self-diagnostic mode, turn the K1000 off. Connect a MIDI cable from the MIDI OUT to the MIDI IN. Hold the C and PLAY\/EDIT buttons while turning the unit on.<\/p>\n<p>The display will show:<\/p>\n<p>KDIAGS MAIN MENU<br \/>>BURN IN<\/p>\n<p>Press the PROGRAM UP button and it will display:<\/p>\n<p>KDIAGS MAIN MENU<br \/>>RUN ALL<\/p>\n<p>Press YES and the display will read:<\/p>\n<p>NUMBER OF PASSES<br \/>> 1<\/p>\n<p>Press YES again to begin the process. The display will test:<\/p>\n<p>Program ROM test<br \/>Setup ROM test<br \/>RAM test<br \/>Battery backup test<br \/>Timer test<br \/>UART test<br \/>VLSI 1 test<br \/>VLSI 2 test<br \/>Sound ROM test<br \/>One sample test<\/p>\n<p>Eventually you will see a display for the sine wave test:<\/p>\n<p>SINE WAVE<br \/>Step 1        1000 Hz<\/p>\n<p>Press any button to step through the sine wave test&#8217;s 11 steps or press NO to skip to the next test, the LCD test, which runs automatically. When it&#8217;s finished, the button test begins.<\/p>\n<p>Pressing each button in turn should display the button&#8217;s function. Press NO twice to exit. When finished, it will display:<\/p>\n<p>PASSES>00001<br \/>ERRORS>00000<\/p>\n<p>If the ERRORS displays anything other than 00000, you may need to have it serviced.<\/p>\n<p>NOTE: if you do not connect the MIDI cable connection loop, it will display at least one failure and will generate a number of errors.<\/p>\n<p>After displaying the test results, the K1000 will return to the >BURN IN display. Press PROGRAM DOWN and the display will read:<\/p>\n<p>KDIAGS MAIN MENU<br \/>>EXIT<\/p>\n<p>Press YES to return to play mode.<\/p>\n","protected":false},"featured_media":0,"template":"","categories":[],"tags":[33927],"storecat":[],"itemids":[],"manufacturers":[33482],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"description\" content=\"Check out the How do I perform self-diagnostics on the Kurzweil K1000? page at Sweetwater \u2014 the world&#039;s leading music technology and instrument retailer!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How do I perform self-diagnostics on the Kurzweil K1000? - SweetCare\" \/>\n<meta property=\"og:description\" content=\"Warning &#8211; the RAM test will erase the K1000&#8217;s memory and will delete all of the program changes you have made, including the master parameter and control settings. Also &#8211; Set the volume to minimum; The sound ROM test generates full-volume waveforms which can damage your audio system. To enter self-diagnostic mode, turn the K1000 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/\" \/>\n<meta property=\"og:site_name\" content=\"SweetCare\" \/>\n<meta property=\"article:modified_time\" content=\"2007-04-27T00:00:00+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/\",\"name\":\"SweetCare\",\"description\":\"Service and Support\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/#webpage\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/\",\"name\":\"How do I perform self-diagnostics on the Kurzweil K1000? - SweetCare\",\"isPartOf\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\"},\"datePublished\":\"2003-07-01T00:00:00+00:00\",\"dateModified\":\"2007-04-27T00:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"How do I perform self-diagnostics on the Kurzweil K1000?\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"description":"Check out the How do I perform self-diagnostics on the Kurzweil K1000? page at Sweetwater \u2014 the world's leading music technology and instrument retailer!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/","og_locale":"en_US","og_type":"article","og_title":"How do I perform self-diagnostics on the Kurzweil K1000? - SweetCare","og_description":"Warning &#8211; the RAM test will erase the K1000&#8217;s memory and will delete all of the program changes you have made, including the master parameter and control settings. Also &#8211; Set the volume to minimum; The sound ROM test generates full-volume waveforms which can damage your audio system. To enter self-diagnostic mode, turn the K1000 [&hellip;]","og_url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/","og_site_name":"SweetCare","article_modified_time":"2007-04-27T00:00:00+00:00","twitter_card":"summary","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website","url":"https:\/\/www.sweetwater.com\/sweetcare\/","name":"SweetCare","description":"Service and Support","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/#webpage","url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/","name":"How do I perform self-diagnostics on the Kurzweil K1000? - SweetCare","isPartOf":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website"},"datePublished":"2003-07-01T00:00:00+00:00","dateModified":"2007-04-27T00:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/perform-self-diagnostics-kurzweil-k1000\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sweetwater.com\/sweetcare\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/"},{"@type":"ListItem","position":3,"name":"How do I perform self-diagnostics on the Kurzweil K1000?"}]}]}},"_links":{"self":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/26749"}],"collection":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/types\/articles"}],"version-history":[{"count":0,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/26749\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/media?parent=26749"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/categories?post=26749"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/tags?post=26749"},{"taxonomy":"storecat","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/storecat?post=26749"},{"taxonomy":"itemids","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/itemids?post=26749"},{"taxonomy":"manufacturers","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/manufacturers?post=26749"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}