{"id":14823,"date":"2002-05-30T00:00:00","date_gmt":"2002-05-30T00:00:00","guid":{"rendered":"http:\/\/www.sweetwater.com\/sweetcare\/?p=14823"},"modified":"2007-04-27T00:00:00","modified_gmt":"2007-04-27T00:00:00","slug":"dr8-dr16-sync-sequencer-done","status":"publish","type":"articles","link":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/","title":{"rendered":"I want my DR8 \/ DR16 to sync to my sequencer. Can this be done?"},"content":{"rendered":"<p>A: No and yes (or vise versa). The HD recorders will never sync to incoming MTC or MIDI Clock + SPP, but you can create a situation in which you can control most common transport commands of the HD recorders from out your sequencer, provided your sequencer can handle MIDI Machine Control. You will need to connect both MIDI In from the sequencer to the MIDI Out of the HD recorder and the MIDI Out of the sequencer to the MIDI In of the HD recorder, because the sequencer will send, for example, a Play command to the DR-4\/8\/16 and the HD recorder will subsequently react on that by sending MTC or MIDI Clock (or whatever timecode it is able to generate simultaneously) back to the sequencer, making the sequencer follow the requested operation. In most cases even individual Track Arming can be done from the sequencer. This actually give the fell of the recorder being slaved to the sequencer although, in reality, the recorder is the source of the timecode.<\/p>\n","protected":false},"featured_media":0,"template":"","categories":[1],"tags":[34531,34226],"storecat":[],"itemids":[],"manufacturers":[33165],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"description\" content=\"Check out the I want my DR8 \/ DR16 to sync to my sequencer. Can this be done?  page at Sweetwater \u2014 the world&#039;s leading music technology and instrument retailer!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"I want my DR8 \/ DR16 to sync to my sequencer. Can this be done?  - SweetCare\" \/>\n<meta property=\"og:description\" content=\"A: No and yes (or vise versa). The HD recorders will never sync to incoming MTC or MIDI Clock + SPP, but you can create a situation in which you can control most common transport commands of the HD recorders from out your sequencer, provided your sequencer can handle MIDI Machine Control. You will need [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/\" \/>\n<meta property=\"og:site_name\" content=\"SweetCare\" \/>\n<meta property=\"article:modified_time\" content=\"2007-04-27T00:00:00+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/\",\"name\":\"SweetCare\",\"description\":\"Service and Support\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/#webpage\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/\",\"name\":\"I want my DR8 \/ DR16 to sync to my sequencer. Can this be done? - SweetCare\",\"isPartOf\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\"},\"datePublished\":\"2002-05-30T00:00:00+00:00\",\"dateModified\":\"2007-04-27T00:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"I want my DR8 \/ DR16 to sync to my sequencer. Can this be done?\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"description":"Check out the I want my DR8 \/ DR16 to sync to my sequencer. Can this be done?  page at Sweetwater \u2014 the world's leading music technology and instrument retailer!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/","og_locale":"en_US","og_type":"article","og_title":"I want my DR8 \/ DR16 to sync to my sequencer. Can this be done?  - SweetCare","og_description":"A: No and yes (or vise versa). The HD recorders will never sync to incoming MTC or MIDI Clock + SPP, but you can create a situation in which you can control most common transport commands of the HD recorders from out your sequencer, provided your sequencer can handle MIDI Machine Control. You will need [&hellip;]","og_url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/","og_site_name":"SweetCare","article_modified_time":"2007-04-27T00:00:00+00:00","twitter_card":"summary","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website","url":"https:\/\/www.sweetwater.com\/sweetcare\/","name":"SweetCare","description":"Service and Support","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/#webpage","url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/","name":"I want my DR8 \/ DR16 to sync to my sequencer. Can this be done? - SweetCare","isPartOf":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website"},"datePublished":"2002-05-30T00:00:00+00:00","dateModified":"2007-04-27T00:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/dr8-dr16-sync-sequencer-done\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sweetwater.com\/sweetcare\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/"},{"@type":"ListItem","position":3,"name":"I want my DR8 \/ DR16 to sync to my sequencer. Can this be done?"}]}]}},"_links":{"self":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/14823"}],"collection":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/types\/articles"}],"version-history":[{"count":0,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/14823\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/media?parent=14823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/categories?post=14823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/tags?post=14823"},{"taxonomy":"storecat","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/storecat?post=14823"},{"taxonomy":"itemids","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/itemids?post=14823"},{"taxonomy":"manufacturers","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/manufacturers?post=14823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}