{"id":12203,"date":"2001-09-27T00:00:00","date_gmt":"2001-09-27T00:00:00","guid":{"rendered":"http:\/\/www.sweetwater.com\/sweetcare\/?p=12203"},"modified":"2007-04-27T00:00:00","modified_gmt":"2007-04-27T00:00:00","slug":"wiring-blue-max-for-230-v","status":"publish","type":"articles","link":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/","title":{"rendered":"Wiring a Blue Max for 230 V"},"content":{"rendered":"<p>The transformer in the BlueMax is designed to operate at 110v or 230v depending on the internal configuration.   Jumpers must be changed internally to achieve the desired operational voltage. A switching type transformer is  usually found in computers and appliances that cost far more than a BlueMax and are also usually not  acceptable in audio applications, as they are inherently noisy. It would be best to purchase PreSonus products<br \/>from a local dealer and be assured the product is set-up to operate at the correct voltage required in your home country.<\/p>\n<p>Preparing a Bluemax for 230 VAC Operation<\/p>\n<p>Tools that you will need:<\/p>\n<p>Soldering Iron and solder, Needle nose pliers and wire cutters Phillips screwdriver 15 mm wrench, Procedure:<br \/>1 . Using the Phillip&#8217;s screwdriver, remove the top cover screws (6), and the front panel screws (4).<br \/>2. Using the 15 mm wrench, remove the hex nuts (5) from the rear panel that secure the 1\/4&#8243; audio jacks.<br \/>3. Disconnect the 4-conductor power cable near transformer, and remove the circuit board assembly from the chassis.<br \/>4. Using the soldering iron and pliers, heat and remove BOTH of the existing wire jumpers. Save ONE jumper that will be reused. Refer to the attached drawing if necessary.<br \/>5. Using the soldering iron and pliers, insert ONE wire jumper into the location that was previously unused. This is the pair of holes closest to the 4-pin power connector.<br \/>6. Use the wire cutters to make sure that any excess wire is clipped from the bottom side of the circuit board.  IMPORTANT: Leaving excess wire exposed could cause an electrical short, resulting in damage to the unit.<br \/>7. Reassemble unit.<\/p>\n<p>   <\/p>\n","protected":false},"featured_media":0,"template":"","categories":[1],"tags":[],"storecat":[],"itemids":[19501],"manufacturers":[33631],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"description\" content=\"Check out the  Wiring a Blue Max for 230 V page at Sweetwater \u2014 the world&#039;s leading music technology and instrument retailer!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wiring a Blue Max for 230 V - SweetCare\" \/>\n<meta property=\"og:description\" content=\"The transformer in the BlueMax is designed to operate at 110v or 230v depending on the internal configuration. Jumpers must be changed internally to achieve the desired operational voltage. A switching type transformer is usually found in computers and appliances that cost far more than a BlueMax and are also usually not acceptable in audio [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/\" \/>\n<meta property=\"og:site_name\" content=\"SweetCare\" \/>\n<meta property=\"article:modified_time\" content=\"2007-04-27T00:00:00+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/\",\"name\":\"SweetCare\",\"description\":\"Service and Support\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/#webpage\",\"url\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/\",\"name\":\"Wiring a Blue Max for 230 V - SweetCare\",\"isPartOf\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/#website\"},\"datePublished\":\"2001-09-27T00:00:00+00:00\",\"dateModified\":\"2007-04-27T00:00:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\/\/www.sweetwater.com\/sweetcare\/articles\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Wiring a Blue Max for 230 V\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"description":"Check out the  Wiring a Blue Max for 230 V page at Sweetwater \u2014 the world's leading music technology and instrument retailer!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/","og_locale":"en_US","og_type":"article","og_title":"Wiring a Blue Max for 230 V - SweetCare","og_description":"The transformer in the BlueMax is designed to operate at 110v or 230v depending on the internal configuration. Jumpers must be changed internally to achieve the desired operational voltage. A switching type transformer is usually found in computers and appliances that cost far more than a BlueMax and are also usually not acceptable in audio [&hellip;]","og_url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/","og_site_name":"SweetCare","article_modified_time":"2007-04-27T00:00:00+00:00","twitter_card":"summary","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website","url":"https:\/\/www.sweetwater.com\/sweetcare\/","name":"SweetCare","description":"Service and Support","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sweetwater.com\/sweetcare\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/#webpage","url":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/","name":"Wiring a Blue Max for 230 V - SweetCare","isPartOf":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/#website"},"datePublished":"2001-09-27T00:00:00+00:00","dateModified":"2007-04-27T00:00:00+00:00","breadcrumb":{"@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/wiring-blue-max-for-230-v\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sweetwater.com\/sweetcare\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/www.sweetwater.com\/sweetcare\/articles\/"},{"@type":"ListItem","position":3,"name":"Wiring a Blue Max for 230 V"}]}]}},"_links":{"self":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/12203"}],"collection":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles"}],"about":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/types\/articles"}],"version-history":[{"count":0,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/articles\/12203\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/media?parent=12203"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/categories?post=12203"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/tags?post=12203"},{"taxonomy":"storecat","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/storecat?post=12203"},{"taxonomy":"itemids","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/itemids?post=12203"},{"taxonomy":"manufacturers","embeddable":true,"href":"https:\/\/www.sweetwater.com\/sweetcare\/wp-json\/wp\/v2\/manufacturers?post=12203"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}